Item Number. 2N8378. Item Name. Baxter Clearlink/Interlink IV Catheter Needleless Extension Set. Shipping. Get FREE ground shipping on all orders 175 . Pay 10.50 for ground shipping on orders under 175. Enter your shipping zip code below to see your estimated ground delivery date
The Baxter single set can be used both as gravity and in the Sigma Spectrum Infusion pump throughout multiple care areas. The Single Set Technology can reduce the number of set ups and teardowns which can decrease the risk of touch contamination and has shown up to 53 cost savings in IV tubing sets and up to 30 reduction in IV tubing usage.
Replace tubing used to administer blood blood products or fat emulsions within 24 hours of initiating the infusion. This is a Category 1B recommendation. Replace tubing used to administer propofol infusions every 6 or 12 hours when the vial is changed per the manufacturer’s recommendations. This is a Category1A recommendation.
AccessGUDIDINTERLINK Solution Set Injection Site Lever Lock Cannula Male Luer Lock Adapter with Retractable Collar
Primary IV Skills Step by Step Skill Demonstration Using the Baxter IV Pump Preparation Steps Check MD order for IV solution and rate Check IV solution for expiration date leaks and clarity Check patient allergies Perform 3 checks comparing IV label with MAR Know purpose of administration/adverse effects of the IV solution Know actions/safe
Oct 08 2020 SKU 2B1308. 0.9 Sodium Chloride Injection USP 50 mL VIAFLEX Plastic Container Multi Pack 16 bags/overwrap . NDC . Purchase on eServices. Export Displayed Data. Product information last updated Oct.
Baxter Continu Flo Non Vented IV Solution Set is an IVsolution set Clearlink Continu Flo with 3 Clearlink luer activated valves 6in 42in and 90in from male luer lock adapter with retractable collar. Approximately 10 drops/mL. Approximate overall length 109in 2.8m . Set has tubing that is compatible with colleague series volumetric infusion pumps and Flo Gard 6201 and 6301
The Baxter Infusor and Intermate devices utilise Check the expiration date on the label. 6. Check that the name is correct on the label if applicable . 7. Wash your hands with hot water and soap. tubing and uncoil the tube set. Remove the Sterility Protector Cap. Retain for later use.
of IVPB solution to MAR. Recheck expiration date 18. Correctly record medication in EHR or IV Solution Record a. Any pertinent collected data such as volume administered in previous bag. b. Date and time started 19. IVPB a. Close the primary tubing with roller clamp. b.
Baxter #ACT5435 Primary Administration Set Duo Vent 10 Drops mL Drip Rate 103 Inch Tubing 1 Port IV SOL SET MLL INJ SITE DV SPIKE 103 48/CS Features. Dual vent for bag or bottles vent is shipped closed and can be flipped open for use on bottles
Jul 01 2014 If a medical item has a date of manufacture but does not have an expiration date is there a time period to consider as expired For example a ureteral stent dated July 2005. Often there are items such a foley catheters suction catheters syringes left in emergency carts that are there for year
Baxter Healthcare Interlink System Solution Set Duo Vent Spike 92 2.3M Injection Site 10 Drops 2C6419 Case of 48 104.76 104 . 76 21.83/10 Items Currently unavailable.
Dec 15 2020 Our global product portfolio enables clinicians to be more efficient and effective in treating patients at the hospital bedside in the operating theater in critical care units at home and in the dialysis clinic. We are working alongside our partners to find new and smarter ways to improve patient outcomes prevent complications before they become life threatening and increase access to care
3. Gather supplies. You will need IV solution primary IV tubing time label change label alcohol swab and basin or sink. Sterile IV solution. 4. Remove IV solution from outer packaging and gently squeeze. Tear the perforated corner of the outer packaging check colour clarity and expiration date.
Jul 30 2010 what is the states protocol for leaving an opened not spiked IV bag hanging in an or suite taht is unattended. there are no dates on the bag and some bags are being pre hung in trauma rooms. By Bob Burke RN CIC on April 11th 2013 at 10 31 am
The Buretrol Solution Set comes complete with a 150mL Interlink burette and 2 Interlink injection sites 6 and 30 from male luer lock adapter. 60 drops per mL drip chamber filter valve. Tubing is compatible with the Colleague series volumetric infusion pumps and Flo Gard 6201 and 6301 series volumetric infusion pumps. Overall length is 105 .
Although some facilities continue to date every sterilized package and use shelf life practices first in first out other facilities have switched to event related practices. This approach recognizes that the product should remain sterile until some event causes the item to become contaminated e.g. a package becomes torn or wet .
Signature Date Excluding dimensions Excluding bar code dimensions U.S. English Other Language Printed Name Signature Date Excluding dimensions Excluding bar code dimensions U.S. English Other Language BAXTER CONFIDENTIAL INTERNAL USE ONLY Document No. Change No. CP Page 1 of 6 P1 25 JUL 2013 JMC
Mar 20 2014 Methods Fifteen sterile 1 L bags of 0.9 sodium chloride solution were randomly selected for this experiment. Five bags were refrigerated at an average temperature of 5.2 C 5 bags were heated at an average temperature of 39.2 C and 5 bags were stored at an average room temperature of 21.8 C to serve as controls.
Extension set pressure rated smallbore 1 removable SmartSite needle free connector s slide clamp s spin male luer lock. Not made with DEHP. L 8 in L 20 cm PV 0.3 mL fluid path sterile labeled for use with low pressure power injectors up to 325 PSI and maximum flow rate of 10 mL/second. 3.9000.
Baxter service specialist Pedro Perez routinely delivers life saving and sustaining peritoneal dialysis PD solutions and supplies into the homes of patients. One day late in 2020 he was called upon to take extraordinary steps to save a life.
Printed expiration date is strictly for simulation purposes. Simulated IV fluids typically have a one 1 year shelf life. IV Tubing Sets. Baxter Compatible Primary Tubing Sets #IV031405. Approximate set length 100
Cloth wrapped packs sterilized and stored appropriately should have an expiration date of six months from the date of sterilization. Peel packs sterilized and stored appropriately should have an expiration date of one year from the date of sterilization.
Nov 22 2019 Posting Date 22–Nov–2019 Official Date 01–Dec–2019 Expert Committee Compounding Reason for Revision Compliance Postponement In accordance with the Rules and Procedures of the 2015–2020 Council of Experts USP is postponing the official date of Pharmaceutical Compounding Sterile Preparations <797>.
Jul 05 2007 4. Tubing which accompanies special products Albumin Intralipids etc. is for one time use with that product and is then discarded. EQUIPMENT Assemble the following from the nursing unit 1. Appropriate IV tubing 2. IV solution 3. Tape 4. Alcohol wipes 5. Sterile/unsterile gloves 6. Site dressings as appropriate 7. IV tubing label 8.
Aug 19 2015 Thanks for the link iluvivt. No exp date on my primary or secondary IV tubing just the lot number. I m sure the patient end with the cannula has an expiration date but not the pump tubing. Maybe it s on the box they came in but they come to me individually.
Baxter’s Clearlink line of IV products combines standard set technology with unique design characteristics including a non latex clear polycarbonate housing a large easy to swab injection surface and a silicone based double seal design. This cost effective access system aims to eliminate needlestick injuries during IV set access procedures.
Nov 01 2019 Baxter Healthcare Ltd Caxton Way Thetford Norfolk IP24 3SE United Kingdom. . Expiry date. 1600. 1000. 800. 600. 400. 200. Container Label. Code B6669C 2 x 500 ml. Baxter Logo. Clinimix N9G15E Solution for infusion. Clintec Logo. 5.5 Amino Acids with Electrolytes 500 ml and Glucose 15
compatibility may be directed to Baxter. If it is deemed advisable to introduce additives use aseptic technique. For information on adding lipid emulsions see Dosage and Administration 2.4 . a. Prepare medication port. b. Using syringe with 19 to 22 gauge needle puncture resealable medication port
Y Type Blood/Solution Set with Standard Blood Filter 170 to 260 Micron an INTERLINK Injection Site Male Luer Lock Adapter Approximately 10 drops per mL Approximate Length 98 2.5 m . Contains DEHP. Fluid path is sterile.
Open clamp on your IV and on tubing to begin infusion Make sure drops are falling in the drip chamber . 8. The infusion will take minutes/hours. 9. When the bag is empty close clamp on tubing and on your IV. 10. Disconnect tubing from your IV line and put a new cap on end of tubing unless it is due to be thrown away . 11.
Baxter IV solutions >150ml in plastic overwrap can be warmed at max 104 F for up to 14 days. If remove at 14 days can use until manufacturer expiration. Must note on product that cannot
Baxter is one of the world s leading manufacturers of commercially prepared IV solutions in flexible containers. Large Volume Pumps LVP are used to deliver medication and solutions through various routes e.g. Intravenous and epidural for therapeutic and diagnostic purposes. They are designed for more accurate fluid delivery than manually
Jul 06 2018 AccessGUDIDDUO VENT Nitroglycerin Set with DUO VENT Spike PVC Tubing Segment Male Luer Lock Adapter with Retractable Collar
through your IV tubing and into your catheter/port. The expiration date on the label has passed. The medication does not appear to be flowing as expected i.e. size of Baxter Corporation 7125 Mississauga Rd. Mississauga Ontario L5N 0C2 Canada.
19 rows Supply of intravenous IV solutions in the United States. Important Product Info Update on