Nexus TKO Anti Reflux Needleless Connector. The Nexus TKO To Keep Open Anti Reflux technology is designed to deliver I.V. Catheter Patency 24/7 .
Clave IV Connector Technology IV Sets Peripheral IV Catheters Disinfecting Caps IV Solutions IV Solutions and Irrigation roller clamp rotating male luer lock bag hanger and sterile priming cap. Additive Hinge Cap . Bag Spike with Integrated Clave Connector . Neutron Needlefree Catheter Patency Device
A low cost IV system designed for 24 hour use that provides protection from accidental needle stick injuries and an effective barrier against microbial contamination 1 Anti siphon Valve 1 Antimicrobial 1 ChemoClave Additive Port 2 Clave Additive Port Dry Spike Adapter 1 Clave Connector 2 Clave Needleless Port Luer Lock Blue
SmartSite needle free connector. Not made with DEHP. PV 0.11 mL labeled for use with low pressure power injectors up to 325 PSI and maximum flow rate of 10 mL/second. 1.1000. Mexico. 0. 0.11. 8.25in x 7.25in x 6.375in 1.1lb. Yes.
Jul 01 2009 I just returned from a meeting and was told that you never under any circumstances put a clave on the port tubing. I was told that even if I sent a person home with a port accessed and no infusion running I was not to use a clave but to use a syringe cap. The reason given was the negative preasure clave would pull blood into the catheter and cause clotting.
The Clave was introduced in 1992 as the first one piece closed needlefree connector. It is the unique design of the Clave that ensures compliance with needlefree policies because of its passive technology which cannot accept a needle. The Clave requires no additional components or adapters to access and requires no end cap for sterility.
MicroCLAVE Needle Free IV Sets and Accessories The MicroCLAVE product line is one of Zoetis innovative solutions to the fluid therapy needs of veterinary professionals. MicroCLAVE products integrate easily with existing IV products or they can replace current IV sets and accessories completely. The needle free design and closed sealing mechanism help maximize safety and efficiency by
microorganisms. Mask required as changing the cap opens the closed system of IV catheter. 4. ENSURE there is a needleless connector attached to the end of the vascular access line. If IV therapy infusing CLAMP catheter and STOP IV infusion. IV lines will be disconnected with old needleless connector. Stopping the infusion will ensure no
MicroClave Clear Connectors and Extensions. Designed with Clave technology of clear housing to help you see the connector flushing after blood draws or administration for accuracy. Provides effective barrier against bacteria transfer and contamination with mechanical microbiologic closed system to help reduce infection risk.
These small IV port caps offer big outcomes by creating an antiseptic barrier to reduce central line associated bloodstream infections. Inside the cap is an impregnated sponge containing isopropyl alcohol to effectively kill bacteria for up to seven days. Types of Connectors Adapters
SwabCap’s patented disinfecting cap design has been shown to help enhance the barrier to bacterial ingress while helping you standardize disinfection protocols. 2 Unlike other caps that only disinfect upon application SwabCap continues to disinfect the connector surface for up to seven days until removed.
Help enhance safety and efficiency by choosing i ndustry leading infection control technology 1 When you choose ICU Medical needlefree IV sets and connectors with patented Clave technology you get an effective barrier against bacterial transfer and colonization designed to help reduce the risk of bloodstream infections.
View Products 4 4 Products. Compatible Connector. Shelf Life. Curos Jet Disinfecting Cap for Needleless Connectors 3M Curos Disinfecting Cap for Needleless Connectors 3M Curos Stopper Disinfecting Cap for Open Female Luers 3M Curos Disinfecting Cap for Tego Hemodialysis Connectors CTG1 270.
1 Spinning Spiros CSTD Male Luer with Cap 1 CSTD Bag Spike with Clave Additive Port and Dry Spike Adaptor 1 Priming Cap Secondary IV Kit CH3322 This kit allows you to create a closed system to protect against spills and leaks during preparation transport administration and disposal eliminating the need to spike and unspike bags on the
Take the disinfectant cap off the Clave and put it aside. Clean the Clave. Using the Site Scrub scrub with back and forth motion for 10 seconds and let dry for 5 seconds. If using an alcohol pad wipe the end of the Clave 8 seconds on the top and 8 seconds around the rim in the grooves and let dry for 15 seconds. Do not blow on or fan the Clave.
Yellow Cap for use with PCA Vial. Yellow cap for use with PCA Vial. Natural rubber latex has not been used in the manufacture of the device. Product Numbers List Number shop.icumed Number EDI Number. Case Information Order Quantity 1 Case 500 Case Size 20 x 25. Pump Line LifeCare PCA . Pump Type Pump Accessory.
Red Cap Dual Function Luer Lock Plug 20 Pack Sterile for Male Or Female Connectors Syringes Tips IV Admin Sets R2000B R2000 4.7 out of 5 stars 48 2 offers from 10.99
Replacement Cap for IV Administration Set 1 Rubber Stoppered Vials Aspiration and Injection 1 Safline Split Septum Injection Site 1 Safsite Needle free System 1 Single Dose Glass Ampules 2 Single Dose Vials 1 Standard Luer Activated Valve 1 Syringe and IV Administration Set 1 Syringes Tube Sets Bag Ports or Other Containers 1
Evaluation of the Clave technology and resistance to microbial ingress. Report of a study commissioned by ICU and conducted by Nelson Laboratories 2008. M1 1212 rev. 03. ICU Medical Study Summary. Observational In Vivo Evaluation of the Neutron Needlefree Catheter Patency Device and its Effects on Catheter Occlusions in a Home Care
Consistent use of Curos disinfecting caps on I.V. needleless connectors is associated with decreased CLABSI. Curos caps are alcohol containing caps that twist onto ports for disinfection and protection. Each Curos cap contains 70 isopropyl alcohol IPA which bathes the
Clave IV Connector Technology IV Sets Peripheral IV Catheters Disinfecting Caps IV Solutions IV Solutions and Irrigation Parenteral Nutrition Male Sterile Cap Male Sterile Cap for capping of male luer adapters. Product Numbers List Number shop.icumed
catheter lumen. Most peripheral IV extension sets also come with clamps particularly those used for intermittent therapy. Clamps are provided so the line can be clamped off when not in use as a safety precaution. This is a common nursing practice which dates back nearly 50 years. Why clamp Patients and personnel are placed at risk when catheter
Clave IV Connector Technology IV Sets Peripheral IV Catheters Disinfecting Caps IV Solutions IV Solutions and Irrigation Parenteral Nutrition Non PVC Non DEHP Containers Oncology Oncology Overview Closed System Transfer Devices CSTDs ChemoLock
Male/Female Sterile Cap for capping male or female luer adapters. Consists of two pieces that separate. Product Numbers List Number shop.icumed Number EDI Number. Sterile Pack Yes. Non DEHP Yes. Latex Information Natural rubber latex has not been used in the manufacture of this product. Case Information Order
Aug 06 2010 Know your connectors. infusionnurse August 6 2010. the devices that allow connections of infusion sets and catheter hubs. Unless you have been living under a rock no one should be using needles to make that connection thus the termneedleless connectors. In a previous blog I posted about an F DA Alert on Positive Displacement
2. 3. The BD MaxZero needle free connector is the zero reflux connector that leverages the same technology as the BD MaxPlus connector designed to help reduce the risk of infections and occlusions. Its low weight and low priming volume make it especially suited for use with all patients including infants and children.
ICU Medical part numbers MC100 CH2003 B9936 B3065 SF B9184 B1115 CH 10 B3108 MC3302 CH 14 CH 51 CH 70 CH 62 CH 13 B6012 CH3034 CH3011 B4020 CS 35 B9909 CH2000S C B3302 SCRC SCXT3 2400 B9286 B9060 B1129
Nov 17 2006 If a postive pressure caps such as the CLC2000 is used the IV can only be clamped AFTER disconnecting the syringeor the injection cap will malfunction. Also if someone attaches a dead end cap to a positive pressure cap when the IV is not in use connection TO the positive pressure caps results in blood reflux into the catheter.
http //curos/products services/curos products/Since the popularization of needleless IV connectors in the 1990s the standard for valve disinfection
Feb 01 1999 In February 1994 Coram Healthcare was using the Clave ICU Medical Irvine CA needleless device . Because of an increasing number of reports regarding iv fluid leaking through the Clave device it was discontinued and the Safsite device Braun Medical Bethlehem PA was introduced at the end of May 1994.
CLAVE Multi Dose Vial Access SpikeGet the lowest price on CLAVE Multi Dose Vial Access Spike online at AllegroMedical. 74.37 CLAVE Multi Dose Vial Access Spike Model 096 5091
After the Clave is clean do not lay it down. 9. Cap the line. Remove the cover from the disinfectant cap and attach the cap to the Clave. Alcohol will spill from the cap and your hand may get wet when you attach the cap to the Clave. This is OK. You may now lay down the line. Loop the line and put on X span mesh if your child is an infant or
Mar 17 2017 This cap is used to cover the male luer end of an IV administration set that is to be reused for an intermittent medication. When you refer to the green caps I think you are actually meaning a disinfection capone brand is bright green. This cap contains alcohol and is not indicated to place directly on an open VAD hub.
May 07 2015 4. injection caps 1. Continuing Education 2. Needleless connectors NCs are devices used to connect catheters administration sets and/or syringes to deliver IV therapy. They were introduced about 20 years ago to prevent needle stick injury to healthcare workers. A Needless Connector automatically seals when the IV set or syringe is removed so that blood or fluids cannot
Sep 08 2009 When rounding on our PICC lines today I came across a PICC line without a cap on the end of the red port and blood visible in the lumen. The nurse states that it must have happened 2.5hours ago after the patient recieved blood. The open ended lumen was lying on the sheets in the patient s bed. The patient is on isolation for MRSA and his diagnosis is pneumonia.
Nov 15 2007 The microclave is a smaller version of clave and has less inflow at disconnection mainly because it has less outflow at connection due to smaller dead space. If lab data is taken out to 1/10000 of an ml amount the microclave still has negative inflows. Its an improvement over clave negative cap